LPF-120W

You are here: Home » Products

LPF-120W

·Universal AC input range/Full range
·Built-in active PFC function
·Protections: Short circuit / Over load/Over voltage/Over temperature
·Cooling by free air convection
·Class II power unit
·IP67 design for indoor or outdoor installations
·Suitable for LED lighting and moving sign applications
·Compliance to worldwide safety regulations for lighting
·Suitable for dry / damp / wet locations
·3 years warranty
E-mail Us  PDF Download
【Prev Products】 【Next Products】

LPF-120WSeries LED driver with PFC

Features:

·Universal AC input range/Full range

·Built-in active PFC function

·Protections: Short circuit / Over load/Over voltage/Over temperature

·Cooling by free air convection

·Class II power unit

·IP67 design for indoor or outdoor installations

·Suitable for LED lighting and moving sign applications

·Compliance to worldwide safety regulations for lighting

·Suitable for dry / damp / wet locations

·3 years warranty

Model

LPF-120-5000

LPF-120-3400

LPF-120-2500

LPF-120-2100

Output

DC voltage

24V

36V

48V

54

Constant current region

16~24V

24~36V

32~48V

32~54V

Rated current

5000mA

3400mA

2500mA

2100mA

Rated power

120W

122.4W

120W

113.4W

Ripple&noise (max.)

3.6Vp-p

4.5Vp-p

4.6Vp-p

4.8Vp-p

Voltage tolerance

±5.0%

Current tolerance

±5.0%

Line regulation

±3.0%

Load regulation

±5.0%

Setup time

1200ms/115VAC,500ms/230VAC(Full load)

Input

Voltage range

90~264VAC 47~63Hz,127~370VDC

AC current(Typ.)

0.8A/115VAC 0.4A/230VAC

Efficiency

89%

90%

91%

91%

Power factor

PF>0.9/230VAC ,PF>0.92/115VAC(at full load)

Inrush current

Cold start current 40A/230VAC

Leakage current

<0.75mA/240VAC

Protection

Overload

95~110% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Over voltage

30~ 33V

44~ 47V

52~ 62V

63~68V

Protection type : Shut down o/p voltage, re-power on to recover

Short circuit

Hiccup mode, recovers automatically after fault condition is removed

Over temperature

90℃±10℃(RTH2)

Protection type : Shut down o/p voltage, re-power on to recover

Environment

Working temp, humidity

-30℃~+50℃,20%~90%RH non-condensing

Storage temp,humidity

-40℃~+80℃,10%~95%RH non-condensing

Temp. coefficient

±0.03%/℃(0 ~ 50℃)

Vibration

10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes

Safety&EMC

Safety standard

UL8750, TUV EN61347-1,EN61347-2-13,UL60950-1,IP67 Certificated

Withstand voltage

I/P-O/P:3KVAC ,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH

EMC interference

Compliance to EN55015,EN61000-3-2 Class C(≥65% Load)

EMC emission

Compliance to EN61000-3-2 Class C(≥75% Load); EN61000-3-3

EMC immunity

Compliance to EN61000-4-2 ,3,4,5,6,8,11; ENV50204,EN55024,EN61547,light industry level (surge 4KV), criteria B

Others

MTBF

420K hrs min. MIL-HDBK-217F (25℃)

Dimension

204*49*34mm(L*W*H)

Packing

0.62kg/30pcs/19.5kg/0.027 m³/0.95CUFT

NOTE:

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4.. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications,

but please reconfirm special electrical requirements for some specific system design.

5.Derating may be needed under low input voltage. Please check the static characteristics for more details.

6.Setup time is measured at cold start condition. Turning ON/OFF the power supply frequently may increase the set up time.

7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will

be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

Send Inquiry

If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.

Related Products