HLG-100W

You are here: Home » Products

HLG-100W

​·universalACinput
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3 Year warranty
E-mail Us  PDF Download
【Prev Products】 【Next Products】

HLG-100W series Full function adjustable waterproof power supply

Features:

·universalACinput

·BUilt-in power factor correction

·Protections:short circuit/over load/over voltage/over temp

·Cooling by free air convection

·OCP point adjustable through output cable or internal potentiometer

·IP67/65 design for indoor or outdoor installations

·Suitble for LED lighting and moving sign applications

·3 Year warranty

Model

HLG-100-12

HLG-100-20

HLG-100-24

HLG-100-36

HLG-100-48

output

DC voltage

12V

20V

24V

36V

48V

Constant current region

6~12V

10~20V

12~24V

18~36V

24~48V

Rated current

5A

4.8A

4A

2.65A

2A

Rated power

60W

96W

96W

95.4W

96W

Ripple&noise

150mvp-p

150mvp-p

150mvp-p

200mvp-p

200mvp-p

Voltage ADJ range

10.8~13V

17~22V

22~27V

33~40V

43~53V

Current ADJ range

Can be adjusted by internal potentiometer or through output cable

3~5A

3~4.8A

2.5~4A

1.7~2.65A

1.2~2A

input

Voltage range

90~264VAC,47~63HZ,127~370VDC

AC current

1.2A/115VAC,0.55A/230VAC

Power factor

PF>0.95/230VAC,PF>0.98/115VAC Start overload protection

efficiency

90%

93%

93%

93%

93%

Inrush current

Cold start current35A/115VAC,75A/230VAC

Leakage current

< 0.75mA/240VAC

protection

Over current

95%~108%

protection type :Constant current limiting,auto-recovery after fault condition is removed

Short circuit

Hiccup mode,recovers automatically after fault condition is remove

Over voltage

14~17V

23~27V

28~34V

41~46V

54~60V

protection type:Shut down o/p voltage re-power on to recover

Over temperature

100℃±10℃(RTH2)

protection type:Shut down o/p voltage re-power on to recover

environment

Working temp,humidity

-20℃~+60℃,20%~90%RH

Storagetemp,humidity

-40℃~+85℃,10%~95%RH non-condensing

Withstand vibration

10~500HZ,2G10min/1cycle,period for 60 minutes,each axes

safety

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC

Fitstandard

Safety standard

Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved

EMC standard

Fit EN55015,EN61000-3-2ClassC(>60%load):EN61000-3-3

others

Dimension

170*68*40mm (L*W*H)

Weight/packing

1kg/20pcs/21kg/0.03m³/1.07CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

Send Inquiry

If you have any enquiry about quotation or cooperation,please feel free to email us at sales@hwele.net or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.

Related Products